How much physical space do I need to install a Dura-i inverter?
For both Dura i G2 and G3 inverters alike, the clearances around the inverter are the same:
Above - 500mm
Below - 600mm
Front - 1000mm
Left side - 200mm
Right side - 350mm
If you are installing multiple inverters at the same height, we would advise 350mm between each inverter as a minimum.
The physical dimensions for the inverters are:
G2
Height – 494.5mm
Width – 585mm
Depth – 210mm
G3
Height - 533mm
Width – 377mm
Depth – 206mm
When looking at Battery selections the Dura 5 and 16 have no specific clearance requirements however they should be in a well-ventilated space to prevent heat build-up around the unit. Also, that they should be installed away from heat sources, open flames, and flammable materials.
Physical dimensions as a wall-mounted system will be:
Dura5
Height – 690mm
Width – 490mm
Depth – 110mm
Dura16
Height - 860mm
Width – 520mm
Depth – 235mm